Kapnometer Capstar 100 [CWE-CAPxx]

zur CO2 Messung in der Ausatmungsluft kleiner Labortiere wie Maus, Hamster, Ratte, Meerschweinchen

Capstar 100
Bild vergrößern

Kapnometer (CWE) zur CO2 Messung

Kapnometer (CWE) zur CO2 Messung in der Ausatmungsluft kleiner Labortiere wie Maus, Hamster, Ratte, Meerschweinchen

The CAPSTAR-100 Carbon Dioxide Analyzer provides continuous measurement of expired CO2 over the range 0-10 percent. Its rapid response time, small sample flow requirements, and long-term stability make it ideal for respiratory gas measurement of rodents and larger animals.

The heart of the instrument is a miniature infrared analyzer with exceptional stability, low maintenance, and a linear output. The heated measurement cell prevents water condensation. The SENSORPOD, which contains the infrared measurement cell, attaches to the front panel by a 1.5m cable. This cell can be removed for cleaning, inspection, or replacement in minutes. The digital display shows CO2 concentration in percent or mmHg, and allows breath-by-breath peak end-tidal reading or continuous rapid response. Calibration is performed with a single calibrated gas and room air.

The reliability and ease of operation of the CAPSTAR-100 make it the perfect instrument for routine respiratory CO2 monitoring. It is the natural companion to our SAR-830 series Small Animal Ventilators for monitoring respiratory status. With the AVS-1 Advanced Ventilator System, it can control end-tidal CO2. It can also be used to monitor unassisted animals. Gas sampling rates of less than 30ml/min can be used, making it possible to monitor animals as small as rats. The fast response time of the CAPSTAR-100 allows end-tidal response plateaus with respiratory rates of 120 breaths/min or greater.

A range of accessories is available to ensure easy setup and convenient operation. An accessory pack containing sample tubing, moisture traps, and Nafion® moisture- absorbing sample tubes is included with the instrument.

Standard Features

  • End-tidal peak or continuous readings
  • Low sample flow requirements
  • Accurate and stable monitoring
  • Linear output signal for recording
  • Sample Flow 30 - 100 ml per minute

Applications

  • Respiratory monitoring
  • Use with ventilated or unassisted animals
  • Suitable for rats and larger animals
  • CO2 control with AVS-1 Ventilator